- Laser Beauty Equipment[9]
- Contactors[15]
- Alternative Energy Generators[1]
- Other Generators[4]
- Power Distribution Equipment[3]
- Other Power Supplies[4]
- Switching Power Supply[4]
- Wiring Harness[1]
- Other Electronic Components[16]
- Emergency & Clinics Apparatus[1]
- Physical Therapy Equipments[8]
- Storage Trays[2]
- Cups & Saucers[1]
- Electric Kettles[2]
- Other Water Heaters[1]
- Baking Equipment[3]
- Other Food Processing Machinery[1]
- Laser Equipment Parts[2]
- Other Machinery[3]
- Other Refrigeration & Heat Exchange Equipment[1]
- Pressure Gauges[28]
- Other Mechanical Parts[1]
- Time Recording[6]
- Fingerprint Access Control[3]
- Locks[1]
- Other Service Equipment[1]
- Other Hotel & Restaurant Supplies[18]
- Telecom Parts[1]
- Wireless Networking Equipment[2]
- Aviation Accessories[2]
M082 Hot Cathode Super-high Ionization Vacuum Gauge
M082 series hot cathode super-high vacuum ionization gauge is a typical B-A gauge and using cathode iridium-core electrophores.
M082 hot cathode super-high vacuum ionization gauge is a typical B-A super-high vacuum ionization gauge with its grid adopting relatively thick tungsten filament, double helix for top supporting for joule exhaust, and using cathode iridium-core electrophoresis yttria for strong anti-oxidation and long life. This gauge can be interchanged with 571 of Varian, G-75-P made by G-P Inc. and RG-75 made by Veeco (U.S.A.).
Major Technical Specifications:
1. Measuring Range: 1*10-1- 4*10-7Pa
2. X Ray Limit: about 4*10-8Pa.
3. Gauge Sensitivity: 0.075 Pa-1 N2
4. Operation Parameters:
Voltage over Ground of Grid: 180 V
Voltage over Ground of Filament: 30 V
Voltage over Ground of Collecting Electrode: 0 V
Emission Current: 2 mA
5. Joule Exhaust: 7.5 V, 10 A
6. Diameter of Connection Tube: Φ19.3,Φ25.4
M082A hot cathode super-high vacuum ionization gauge is a typical B-A super-high vacuum ionization gauge with its grid adopting relatively thick tungsten filament, double helix for top supporting for joule exhaust, and using cathode iridium-core electrophoresis yttria for strong anti-oxidation and long life. This gauge can be interchanged with 571 of Varian, G-75-P made by G-P Inc. and RG-75 made by Veeco (U.S.A.).
Major Technical Specifications:
1. Measuring Range: 1*10-14*10-7Pa
2. X Ray Limit: about 4*10-8Pa
3. Gauge Sensitivity: 0.075 Pa-1N2
4. Operation Parameters:
Voltage over Ground of Grid: 180 V
Voltage over Ground of Filament: 30 V
Voltage over Ground of Collecting Electrode: 0 V
Emission Current: 2 mA
5. Joule Exhaust: 7.5 V, 10 A
6. Diameter of Connection Tube: Φ19.3,Φ25.4
M082B hot cathode super-high vacuum ionization gauge is a typical B-A super-high vacuum ionization gauge with its grid adopting relatively thick tungsten filament, double helix for top supporting for joule exhaust, and using cathode iridium-core electrophoresis yttria for strong anti-oxidation and long life. This gauge can be mutually replaced with 571 of Varian, G-75-P made by G-P Inc. and RG-75 made by Veeco (U.S.A.).
Major Technical Specifications:
1. Measuring Range: 1*10-1- 4*10-7Pa
2. X Ray Limit: < 4*10-8Pa
3. Gauge Sensitivity: 0.05 Pa-1N2
4. Operation Parameters:
Voltage over Ground of Grid: 200 V
Voltage over Ground of Filament: 30 V
Voltage over Ground of Collecting Electrode: 0 V
Emission Current: 0.1 - 2 mA.
5. Joule Exhaust: 10 V, 9 A
6. Diameter of Connection Tube: DN 40 KF