- Laser Beauty Equipment[9]
- Contactors[15]
- Alternative Energy Generators[1]
- Other Generators[4]
- Power Distribution Equipment[3]
- Other Power Supplies[4]
- Switching Power Supply[4]
- Wiring Harness[1]
- Other Electronic Components[16]
- Emergency & Clinics Apparatus[1]
- Physical Therapy Equipments[8]
- Storage Trays[2]
- Cups & Saucers[1]
- Electric Kettles[2]
- Other Water Heaters[1]
- Baking Equipment[3]
- Other Food Processing Machinery[1]
- Laser Equipment Parts[2]
- Other Machinery[3]
- Other Refrigeration & Heat Exchange Equipment[1]
- Pressure Gauges[28]
- Other Mechanical Parts[1]
- Time Recording[6]
- Fingerprint Access Control[3]
- Locks[1]
- Other Service Equipment[1]
- Other Hotel & Restaurant Supplies[18]
- Telecom Parts[1]
- Wireless Networking Equipment[2]
- Aviation Accessories[2]
Thermal Couple Vacuum Gauge
JZ-51, M007, JZ-53 and JZ-54 series thermal couple gauge are a kind of low vacuum gauge head having the advantage of simple in;
ZJ-51 and M007 series long filament thermal couple (TC) is a kind of low vacuum gauge used in the earliest time at home, having the merits of simple in structure and convenient for operation. Its cover employs DM-305 glass, aluminum alloy, stainless steel, etc..
Major Technical Specifications:
1. Measuring Range: 6.65*101 1.33*10-1 Pa.
2. Filament Current: 90 - 130 mA.
3. Within the range of 13Pa1Pa, relative deviation between the standard curve and the standard characteristic curve is less than +-15%.
4. Vacuum degree within the glass gauge is not less than 5*10-2 Pa before unsealing.
Cautions for Operation:
1. Calibrate the heating current before unsealing.
2. The labeled heating current of the metal gauge can be used as reference for operation.
3. Better install the gauge vertically.
ZJ-53 and ZJ-54 (M713, M714) series short filament thermal couple gauge have the advantages of rapid response, anti-oxidation and stable performance, etc. Its cover adopts DM-305 glass, aluminum alloy, stainless steel, porcelain, etc.
Major Technical Specifications:
1. Measuring Range: 3*1021*10-1 Pa.
2. Heating Current: 27.5+-1.5 mA
3. Response Time: < 3s
4. Within the range of 150Pa, relative deviation between the calibration curve and the standard characteristic curve is less than +-15%.
5. Vacuum degree within the glass gauge is not less than 5*10-2 Pa before unsealing.
Cautions for Operation:
1. Measuring heating current value before unsealing.
2. The labeled heating current of the metal gauge can be referenced for operation.
3. Better use the gauge under vertical installation;